跳到正文
FacilitiesNet HVAC·· 2 小时前次级推荐AI 评分64

「英中对照」AABC发布第八版全系统平衡国家标准,更新暖通空调TAB指南

AABC Updates HVAC Testing and Balancing Standards

AI 导读

联合空气平衡委员会(AABC)10月20日发布第八版《全系统平衡国家标准》,为2016年以来首次更新暖通空调测试、调整与平衡(TAB)行业指南。

推荐理由

TAB标准是暖通系统验收与调试的执行依据,本次修订涉及报告要求、仪器校准与测量公差等执行口径,并扩展至地板送风等场景,可能影响设施管理人员与设计专业人员的验收调试流程;目前修订细节来自AABC新闻稿,具体条款仍需以标准原文为准。

正文 · 原文

Their eighth edition updates industry guidance for testing, adjusting and balancing (TAB) HVAC systems for the first time since 2016.   October 20, 2026

The Associated Air Balance Council (AABC) has published the eighth edition of its National Standards for Total System Balance, updating industry guidance for testing, adjusting and balancing (TAB) HVAC systems for the first time since 2016. 

The American National Standards Institute (ANSI)-approved manual establishes minimum standards for total system balance, outlines TAB agency responsibilities and provides procedures intended to help design professionals achieve building system design intent. 

“It's important to keep updating the standards because the industry is changing,” says Gaylon Richardson, AABC Standards Committee chairman and representative of Engineered Air Balance Co. Inc., in a press release shared with FacilitiesNet. 

The eighth edition includes revisions to TAB reporting requirements, instrumentation and calibration standards, measurement tolerances and Pitot tube traverse procedures. It also adds guidance on fan laws, fan system equations and total leakage recommendations for air leakage testing. 

FacilitiesNet Recommends: Common HVAC Missteps and Myths

Other updates address testing procedures for constant- and variable-volume systems, energy recovery and temperature control systems, cooling towers, boiler plants, laboratories, kitchens and smoke control systems. The manual also includes new information on air flow-limiting devices (AFLDs) and pressure-independent control valves (PICVs). 

The commissioning chapter has been rewritten to provide updated information on HVAC commissioning and commissioning plans. An entirely new chapter expands coverage of underfloor air distribution systems. 

Like the seventh edition, the latest version received approval from ANSI. According to AABC, the designation indicates that the standards development process meets ANSI requirements for openness, balance, consensus and due process. 

For facility managers, the updated guidance provides a reference for understanding TAB procedures and requirements when verifying HVAC system performance. Proper testing and balancing can help determine whether systems operate as intended and deliver the airflow and other conditions established during design. 

The eighth edition of the National Standards for Total System Balance is available through AABC's website. 

Jeff Wardon, Jr., is the assistant editor for the facilities market. With more than three years of experience, he covers topics including technology, wellness, sustainability and emerging industry trends. Connect with him on LinkedIn.


来源:FacilitiesNet HVAC · facilitiesnet.com